Sign In | Join Free | My frbiz.com |
|
Type : Integrated type, BGT-W818
Place of Origin : Beijing, China
Brand Name : BGT
Model Number : BGT-W818
Key word : Air quality station sensor
Measuring elements : tem, humi, PM2.5 PM10 CO NO2 SO2 O3
Power Supply : DC12V/24V
Output signal : RS485 (Modbus protocol)
Measuring range : PM2.5/PM10:0~1000μg/m3; Temperature:-40~60℃;Humidity:0~100%RH
Accuracy : PM2.5/PM10:±10% OR ±10μg/m3,Temperature:±0.3℃ Humidity:±3%RH
Resolution : PM2.5/PM10:1μg/m3,Temperature:0.01 ℃ Humidity:0.01%RH
Cable Length : 3M
Response time : ≤120s
Packaging Details : Cartons
Price : $1,698.20/pieces 1-9 pieces
MOQ : 1 piece
2020 BGT Professional Temperature Humidity Air Quality Monitor PM2.5 PM10 CO NO2 SO2 O3 Weather Station Sensor
BGT-W818 Air quality sensor (Outdoor type) is an instrument for monitoring six pollutant parameters including PM2.5, PM10, CO, SO2, NO2 and O3, as well as air temperature and relative humidity.The main function is to monitor the conventional pollution factors in the air for 24-hour continuous online. In addition, hydrogen sulfide, volatile organic pollutants, total suspended particulate matter and other meteorological sensors (wind speed, wind direction, atmospheric pressure, rainfall, solar radiation) can be optional.
Product | BGT-W818 Air quality sensor | ||||
Type | BGT-W818 | ||||
Measuring Range | PM2.5/PM10:0~1000μg/m³; Temperature:-40~60℃; Humidity:0~100%RH; CO:0-12.5ppm SO2: 0-2000ppb NO2: 0-2000ppb O3: 0-2000ppb | ||||
Resolution | PM2.5/PM10:1μg/m³; Temperature:0.01 ℃; Humidity:0.01%RH; CO:≤10ppb SO2: ≤10ppb NO2: ≤10ppb O3: ≤10ppb | ||||
Accuracy | PM2.5/PM10:±10%(<500ug) Temperature:±0.3℃; Humidity:±3%RH; CO: ±1.5%F.S SO2: ±1.5%F.S NO2: ±1.5%F.S O3: ±1.5%F.S | ||||
Power supply | DC12V/24V | ||||
Output | RS485 Modbus communication protocol | ||||
Cable Length | Standard: 3M | ||||
PM minimum resolution particle size | 0.3μm | ||||
Working current | DC12V <80mA(485) ;DC12V <100mA(current) | ||||
Power Consumption | DC12V <1W(485) ;DC12V<1.2W (current) | ||||
Response time | ≤120s | ||||
PM laser life | PM laser life | ||||
Operating environment | Temperature: -40 ~ 70℃,Humidity: 0 ~ 90%RH | ||||
The farthest lead | Current:200 meters, RS485:100 meters,Voltage:50 meters | ||||
Ingress Protection | IP65 |
![]() |